VKD1S00B-AZC00-000 [Carling Technologies]
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,;型号: | VKD1S00B-AZC00-000 |
厂家: | Carling Technologies |
描述: | Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount, 开关 光电二极管 |
文件: | 总14页 (文件大小:3140K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
V-Series
Contura II & III
Switches
The V-Series Contura II & III snap-in rocker switches
offer countless unique options including choices for
ratings, circuits, colors, illuminations and symbols.
These single or double pole switches feature
removable actuators in a choice of actuator styles
and colors, and can be illuminated with either
square or bar shaped lenses. Actuators may be
purchased and stocked separately. An optional
plug-in terminal connector enables pre-wiring of
wire harnesses.
The Contura switches with sealed option, are
certified to IP66 and IP68, signifying complete
protection against dust and prolonged spray and
submersion under pressure, and are recognized to
UL1500 - Ignition Protection for Marine Products.
These switches are vibration, shock, thermoshock,
moisture and salt spray resistant. Temperature
ratings range from -40°C to +85°C.
Product Highlights:
Countless options for ratings, circuits, colors,
illuminations and legends
Certified to IP66 and IP68 for front panel components
Vibration, shock, thermoshock, moisture and salt spray resistant
Temperature range from -40°C to +85°C.
Resources:
Download 3D CAD Files
IGS
STP
Typical Applications:
On/Off Highway Equipment
Marine
Watch Product Video
Military Armored Vehicles
Mining Machinery and Equipment
Any application requiring environmental protection
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: (860) 793-9281 • Fax: (860) 793-9231
www.carlingtech.com
|
2
V-Series Contura Sealed Rocker Switches
V-Series Switch
DESIGN FEATURES
INTERCHANGEABLE ACTUATORS
Panel redesign is a snap with our wide
range of rocker styles. Achieve maximum
design variety with minimum inventory.
Simply swap rockers to create an entirely
new look for your panel.
DUAL SEAL PROTECTION
CLEAN CONNECTIONS
Seals out water, dust,
Options for both eight and ten
terminal base styles with AMP &
Packard compatible connectors
affords myriad circuit options
while providing ease of assembly.
debris, and enables switch
certification to IP66/IP68 for
front panel components.
OPTIONAL PANEL SEAL
Prevents water/dust
ingress behind panel.
MULTIPLE LIGHTING OPTIONS
BRASS ROLLER PIN
Robust mechanism
eliminates the need for
lubricants. Enables switch
to withstand -40°C to
+85°C temperatures.
SILVER PLATED BUTT
CONTACT MECHANISM
Providing 50K to 100K
electrical cycles and
a variety of different
electrical ratings.
In addition to incandescent
lamps, our LED illumination is
offered in a wide array of light
intensities, colors, as well as
dual level, tri-color, and flashing
options.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
V–Series Contura Sealed Rocker Switches - General Specifications
3
Electrical
Agency Certifications
Contact Rating
.4VA @ 24VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
1/2 HP 125-250VAC
20 amps, 4-14VDC
15 amps, 15-28VDC
10A, 14VT
6A, 125VAC L
1500 Volts RMS
50 Megohms
Environmental
Sealing
Sealed version: IP68, in accordance
with IEC 60529, BS 5490, DIN 40050
& NFC 20 010. This rating applies to
front panel components of the actual
switch only, and signifies protection
against dust and the prolonged
effects of immersion under pressure.
The standard test for immersion
under pressure requires submersion
under one meter of water for 30 min.
The V-Series switch has exceeded
these parameters, having
Dielectric Strength
Insulation Resistance
Initial Contact Resistance 10 milliohms max. @ 4VDC
Life
50,000- 100,000 cycles circuit
dependent
Silver alloy, silver tin-oxide, fine
silver
Brass or copper/silver plate 1/4”
(6.3mm) Quick Connect
terminations standard. Solder lug,
Wire Lead
Contacts
Terminals
been actuated and illuminated during
submersion.
Corrosion
Mixed Flowing Gas (MFG) Class III
3 year accelerated exposure per
ASTM B-827, B-845 Silver and gold
contacts
Mechanical
Operating Temp.
Vibration 1
-40°C to +85°C
Endurance
150,000 cycles minimum
circuit dependent
Per Mil-Std 202F, Method 204D
Test Condition A 0.06 DA or 10G’s
10-500 Hz. Tested with VCH connector.
Test criteria - No loss of circuit during
test, pre and post test contact
resistance.
Physical
Lighted
Incandescent - rated 10,000
hours Neon - rated 25,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for
voltages to 24VDC)
Vibration 2
Resonance search
24-50 Hz 0.40 DA
50-2000 Hz ±10 G’s peak
Horizontal Axis 3-5 G’s max.
Random
Seals
Base
Internal
Optional external gasket panel seal
Polyester blend rated to 125°C with
a UL flammability rating of 94V0.
Hard Surface: Basic actuator
structure molded of thermoplastic
polycarbonate with a hard Nylon 66
thermoplastic surface overlay.
Soft Surface: Basic actuator structure
molded of thermoplastic polycarbonate
with an elastomer overlay.
24 Hz 0.06 PSD-Gsq/Hz
60 Hz 0.50
Contura II,III,IV,V,
VI, VII Actuator
100 Hz 0.50
200 Hz 0.025
2000 Hz 0.025
No loss of circuit during test; <10μ
seconds chatter.
Shock
Per Mil-Std 202F, Method 213B, Test
Condition K @ 30G’s. Tested with
VCH connector. Test criteria - No loss
of circuit during test, pre and post
test contact resistance.
Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105°C
Lens
Contura XIV
Polycarbonate rated at 100°C
Polycarbonate lens/subrocker with
ABS shell
Salt Spray
Dust
Per Mil-Std 202F, Method 101D, Test
Condition A, 96 Hrs. Sealed version only.
Per Mil-Std 810C, Method 510.2 Air
Velocity 300 ±200 Feet/Min, Test
Duration 16 Hrs.
Actuator Travel (Angular Displacement)
2 position
3 positions
18°
Thermal Shock
Per Mil-Std 202F, Method 107F, Test
9° from center
Cond. A, -55°C to +85°C. Test criteria -
pre and post test contact resistance
Per Mil-Std 202F, Method 106F, Test
Criteria - pre and post test contact
resistance
All Contura switches with sealed
construction meet the requirements
of UL1500/ISO8846 for ignition
protection, in addition to
conformance with EC directive
94/25/EC for marine products.
Mounting Specifications
Moisture Resistance
Ignition Protection
.830[21.08]
Panel Thickness Range
Gaskets Acceptable Panel Thickness
0
.030 to .250 (.76mm to 6.35mm)
TEST CUT
HOLE IN
ACTUAL
1.450[36.83]
1
.030 to .109 & .147 to .157
MATERIAL
(.76 to 2.77mm & 3.73 to 3.98mm)
Recommended: No gasket with panel
thickness of .032, .062, .093, .125,.187 or .250
SWITCH
MOUNTING HOLE
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
4
V–Series Contura II, III
Dimensional Specifications: in. [mm]
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
V-Series Contura II to XIV - Circuit Diagram
5
CIRCUIT CIRCUIT DIAGRAM
CIRCUIT CIRCUIT DIAGRAM
CIRCUIT CIRCUIT DIAGRAM
3
3
3
3
3
3
3
3
3
6
6
6
6
6
6
6
1
1
1
3
3
3
3
3
3
4
4
4
6
6
6
6
6
6
1
A
B
C
D
E
F
J
K
L
2
3
2
2
2
2
2
2
2
2
5
5
5
5
5
5
5
5
2
2
2
2
2
2
5
5
5
5
5
5
2
2
3
3
2
1
1
1
1
1
3
3
3
3
3
1
1
1
4
4
4
4
5
6
7
8
M
R
S
2
2
2
2
2
1
1
SYMBOL LEGEND
G
H
SYM.
DEFINITION
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
4
DESIGNATES MAINTAINED CIRCUITS
DESIGNATES OTHER POSITION
DESIGNATES MOMENTARY CIRCUITS
DESIGNATES TWO POSITION CONNECTION
DESIGNATES EXTERNAL JUMPER PROVIDED
BY CUSTOMER
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
6
V-Series Contura II to XIV - Circuit Diagram
LAMP
CIRCUIT
LAMP
CIRCUIT
LAMP
CIRCUIT
LAMP
CIRCUIT
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
+3 +6
+8
+8
+3
-6
+3
-6
SPECIAL
#1
1
2
1
1
2
2
2
2
2
1
A/1
B/2
C/3
D/4
E/5
F/6
G/7
H/Z
J/8
L/9
M/R
N/T
P/V
U/Y
-7
-7
-7
+8
+6
+3
+8
+3
+3
-6
SPECIAL
#3
1
2
1
1
2
2
2
-7
-7
-7
+8
+3
+3
+8
+1 +3 -4 -6
SPECIAL
#4
1
2
2
1
-7
-7
-7
-8
+1
+3
+6
+6
+1 +3 -4 -6
+3
1
2
1
1
-7
-7
+8
1
+10
2
+1 +3
+8
1
2
K/W
1
-7
-9
-7
(-)7
CIRCUIT
CIRCUIT
CIRCUIT
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
17 18
CIRCUIT DIAGRAM
NOTE:
1
3
17 18 10(-)
1
1
3
1311 3 14
10(-)
6
J circuits are available for
all non-locking V-Series
styles. Consult factory for
p/n details.
J1
J5
JA
2
2
5
8
2
5
8
5
13 11 3 14
17 18 10(-)
1311 3 14
J2
J3
J4
JJ
1
5
8
1
3
17 18 10(-)
1311 3 14 15 12 6 16
JK
1
2
5
5
8
17 18 10(-)
1
3
SYMBOL LEGEND
CIRCUIT CONNECTOR PART #
1
SYM.
DEFINITION
JA,JJ,JK
J1,J3,J4,J5
J2
JC1-01
JC2-01
JC3-01
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
2
DESIGNATES TWO POSITION CIRCUIT
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
V-Series Contura II & III Sealed Rocker Switches - Ordering Scheme
7
V 1 D A B T 0 B A R B 00 0 00
8
9
10
Lens
11
Color
12
Legend
13
Legend
Orientation Lens Legend
14
Actuator
1
2
3
4
5
6
7
Bracket
Actuator
Series
Circuit
Rating
Termination Illumination Lamp
Lamp
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
1 SERIES
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
V
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
2 CIRCUIT
LED*
Red
superbright superbright
Terminal Connections as viewed
from bottom of switch:
( ) - momentary
Amber
Green
Red
R
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
2VDC
A
B
C
D
L
F
G
H
J
8 terminal 10 terminal
6VDC
M
N
P
S
8 - - 7
1 - - 4
2 - - 5
3 - - 6
8 - - 7
1 - - 4
2 - - 5
3 - - 6
10 - - 9
12VDC
24VDC
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
Position:
1
2 & 3, 5 & 6
ON
2
Connected Terminals
NONE
3
1 & 2, 4 & 5
OFF
SP DP
8 FLUSH BRACKET COLOR1, PANEL SEAL
1
2
3
4
5
6
7
8
A
B
C
D
F
(ON)
ON
NONE
OFF
Black
B
C
White
W
Y
Gray
G
H
NONE
(OFF)
ON
No Seal
One Seal
ON
NONE
ON
NONE
(ON)
J
ON
OFF
ON
K
L
ON
OFF
(ON)
(ON)
OFF
(ON)
9 ACTUATOR
SPECIAL CIRCUITS
0
No Actuator
H*
G*
S*
M*
R*
E*
2 & 3
2 & 3, 5 & 4
2 & 3
5 & 4
OFF
1 & 2
OFF
2 & 1
5 & 1
A, B Contura II
C, D Contura III
2 & 3, 5 & 6
2 & 3, 5 & 6
(2 & 3, 5 & 6)
(2 & 3, 5 & 6)
5 & 6
2 & 3
2 & 3
3,6
1,4
Actuator orientation above terminals:
2 & 3
5 & 3
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
10 LENS
0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue
3 RATING3
1
2
3
4
5
6
7
8
9
A
8
G
H
J
K
L
M
N
P
R
S
T
1
.4VA @ 28VDC Resistive
15A 24V
C
D
E
F
U
V
W
Y
B
C
D
E
F
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
M
N
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
.4VA/15A 24V
4 TERMINATION/BASE STYLE
11 ACTUATOR COLOR1 AND TEXTURE
8 term 10 Term
Termination
Jumper
0 - No Actuator
1
2
.250 TAB (QC) no barriers
.250 TAB (QC) with barriers
.250 TAB (QC) no barriers
Solder Lug no barriers
Solder Lug
Wire Leads no barriers
Wire Leads
No
Black
B
C
Gray
G
H
Red
R
S
White
W
Y
A
J
B
K
5
No
Yes T2 to 5
No
No
No
No
Soft Surface
Hard Surface
3
C
5
D
6
F
12 ACTUATOR LENS OR BODY LEGENDS2
E
Note: Codes J & K for circuits H, G & M.
11 ON
12 OFF
13
I
14 O
OFF
ON
O
I
15 O O 16 O O 17 O I 18 I O
5 ILLUMINATION
F N
F
N
F
F
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed
Unsealed
Lamps
NONE
Illumination Type
–
Lamp wired to Terminals
–
For additional legend options & codes, visit us at www.carlingtech.com.
S
A
B
C
D
0
1
2
3
4
1
1
2
1
2
1
2
1
2
1
2
2
1
2
INDEPENDENT
DOWN
8 (+) 7 (–)
3 (+) 7 (–)
3 (+) 7 (–)
3 (+) 7 (–)
1 (+) 7 (–)
1 (+) 7 (–)
3 (+) 7 (–)
8 (+) 7 (–)
3 (+) 6 (–)
8 (+) 7 (–)
3 (+) 7 (–)
8 (+) 7 (–)
8 (+) 7 (–)
10 (+) 9 (–)
13 LEGEND ORIENTATION
UP
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
DOWN
DOWN
UP
UP
INDEPENDENT
UP
INDEPENDENT
UP
INDEPENDENT
INDEPENDENT
INDEPENDENT
Orientation 1
Orientation 2
Orientation 3
Orientation 4
E
F
5
6
7
G
H
U
Z
Y
14 ACTUATOR LENS LEGEND
SINGLE POLE SWITCHES ONLY
00
No legend this location / no actuator
J
8
1
2
1
2
DOWN
3 (+) 8 (–)
6 (+) 7 (–)
8 (+) 7 (–)
6 (+) 7 (–)
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specified in selection 12; body legend specified in selection 14.
INDEPENDENT
INDEPENDENT
INDEPENDENT
K
W
For legend options & codes, visit us at www.carlingtech.com.
DOUBLE POLE SWITCHES ONLY
L
M
N
9
R
T
1
1
1
2
1
2
DOWN
UP
3 (+) 6 (–)
3 (+) 6 (–)
3 (+) 6 (–)
1 (+) 4 (–)
1 (+) 4 (–)
3 (+) 6 (–)
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
DOWN
DOWN
UP
1
2
Custom colors are available. Consult factory.
Body legends not available on Soft surface actuators; White imprinting is standard
on black actuators; Black imprinting is standard on white, red and gray actuators.
Custom colors are available, consult factory.
P
V
UP
3
4
Additional ratings available. See V-Series Switch Accessories page.
Contura II available with two square lenses. Consult factory for details.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
8
V-Series Contura II & III Locking Sealed Rocker Switches - Ordering Scheme
V 1 D A S W 0 B A Z E 00 0
8
9
10
Lens
11
Function
12
Legend
13
1
2
3
4
5
6
7
Bracket
Actuator
Legend
Orientation
Series
Circuit
Rating
Termination Illumination Lock
Lamp
1 SERIES
V
7 LAMP
Lamp above terminals 3 & 6 end of switch
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
2 CIRCUIT
LED*
Red
superbright superbright
Terminal Connections as viewed
from bottom of switch:
( ) - momentary
Amber
Green
Red
R
SP - single pole - uses terminals 1, 2 & 3.
2VDC
A
B
C
D
L
F
G
H
J
8 terminal 10 terminal
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
6VDC
M
N
P
S
8 - - 7
1 - - 4
2 - - 5
3 - - 6
8 - - 7
1 - - 4
2 - - 5
3 - - 6
10 - - 9
12VDC
24VDC
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
Position:
1
2 & 3, 5 & 6
ON
2
Connected Terminals
NONE
3
1 & 2, 4 & 5
OFF
SP DP
8 FLUSH BRACKET COLOR1, PANEL SEAL
1
4
5
6
7
8
9
A
D
F
J
ON
NONE
ON
Black
B
C
White
W
Y
Gray
G
H
ON
NONE
(ON)
ON
No Seal
One Seal
ON
OFF
K
L
N
ON
OFF
(ON)
(ON)
ON
(ON)
OFF
OFF
NONE
9 HARD SURFACE ACTUATOR1
SPECIAL CIRCUITS
H*
G*
S*
M*
R*
E*
2 & 3
2 & 3, 5 & 4
2 & 3
5 & 4
OFF
1 & 2
OFF
2 & 1
5 & 1
Black
A
Gray
B
Red
G
White
2 & 3, 5 & 6
2 & 3, 5 & 6
(2 & 3, 5 & 6)
(2 & 3, 5 & 6)
5 & 6
Contura II
Contura III
H
2 & 3
2 & 3
C
D
E
F
2 & 3
5 & 3
3,6
1,4
Actuator orientation above terminals:
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
10 LENS
Z - No Lens
Clear White Amber Green Red Blue
3 RATING4
3
8
D
J
P
V
1
.4VA @ 28VDC Resistive
15A 24V
B
C
D
E
F
M
N
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
11 ACTUATOR LOCK FUNCTION AND COLOR1
Lock Color
Match Actuator
Black
White
Red
Up
A
B
C
D
Down
H
J
K
L
Up & Down Center3
.4VA/15A 24V
R
S
T
1
2
3
4
5
4 TERMINATION/BASE STYLE
8 term 10 Term
Termination
Jumper
V
W
1
2
.250 TAB (QC) no barriers
.250 TAB (QC) with barriers
.250 TAB (QC) no barriers
Solder Lug no barriers
Solder Lug
No
Safety Orange
E
M
A
J
B
K
5
No
Yes T2 to 5
No
No
No
No
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
3
C
5
E
D
6
F
Wire Leads no barriers
Wire Leads
21
OFF
22
ON
23
24
O
I
Note: Codes J & K for circuits H, G & M.
25
O
F
F
26 O
27 O
28 I
N
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
For additional legend options & codes, visit us at www.carlingtech.com.
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed
Unsealed
Lamps
Illumination Type
Lamp wired to Terminals
ORIENTATION OF
S
C
H
0
3
Z
NONE
–
–
ACTUATOR/LENS IN PANEL
13 LEGEND ORIENTATION
ORIENTATION
1
2
2
UP
3 (+) 7 (–)
8 (+) 7 (–)
0
1
2
3
4
No legend (used with codes 21-28 in selection 12)
INDEPENDENT
Orientation 1
Orientation 2
Orientation 3
DOUBLE POLE SWITCHES ONLY
M
R
1
UP
3 (+) 6 (–)
ORIENTATION
4
ORIENTATION
2
Orientation 4
AZC45-1
6 LOCK
AZC45-2
45
Lock above terminals 1 & 4 end of switch.
W
lock
45
ORIENTATION
3
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1
2
Custom colors are available. Consult factory.
White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators. Custom colors are available, consult factory.
Only available with 3 position circuits. Center OFF and special circuits only available
with center position lock function.
3
4
Additional ratings available. See V-Series Switch Accessories page.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
V-Series Contura Sealed Rocker Switch Actuators Separately
9
Reduce inventory levels and cost by stocking actuators and base switches separately.
Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes.
Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes.
Contura VI Actuator with lenses and inserts only: VV with code selections 9-16
Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes.
Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes.
Panel Seal: VPS
Contura X & XI actuators without lenses separately:
Contura XII actuators without lenses separately:
VVR 6 1 00 1
VVP J 1 Z 21 1 00
1
2
3
Lens
4
5
1
2
3
Lens
4
Lens
5
6
7
Actuator Separately Actuator
Actuator
Legend
Legend
Orientation
Actuator
Style &
Color
Legend
Legend
Orientation
Legend
Style/Color Opening
Opening Opening
1 CONTURA X & XI ACTUATOR SEPARATELY
VVR
1 CONTURA XII ACTUATOR SEPARATELY
VVP
2 ACTUATOR STYLE & COLOR
2 ACTUATOR STYLE & COLOR
Black
Gray
White
3
8
Red
4
9
J
Black
K Gray
N
White
M Red
Contura X
Contura XI
1
6
2
7
3,4 LENS OPENING FOR
Z
No lens
1
Bar lens
2 Square lens
3 LENS OPENING FOR1
1
One bar lens
5
square lens on top/
bar lens on bottom
(Contura X only)
2
3
4
One bar lenses
One square lens
two square lens
5, 7 LENS OR BODY LEGEND2
00 - No Legend
21
22
23
24
OFF
ON
O
I
25
O
F
F
26 O
27 O
28 I
4 ACTUATOR LENS OR BODY LEGEND
N
00 - No Legend this location
11 ON 12 OFF
OFF ON
13
I
O
14
O
I
For additional legend options & codes, visit us at www.carlingtech.com.
15 O O 16 O O 17 O I 18 I O
ORIENTATION OF
ACTUATOR/LENS IN PANEL
6 LEGEND ORIENTATION3
F N
F
N
F
F
ORIENTATION
1
0
1
2
No legend
For additional legend options & codes, visit us at www.carlingtech.com.
Orientation 1
Orientation 2
ORIENTATION
2
ORIENTATION OF
ACTUATOR/LENS IN PANEL
5 LEGEND ORIENTATION1
ORIENTATION
1
0
1
2
3
4
No legend
Contura X, XI & XII actuator lens assembly separately:
Orientation 1
Orientation 2
Orientation 3
Orientation 4
ORIENTATION
4
ORIENTATION 2
VVL 2 1 00 0
1
2
3
4
5
Lens Separately
Lens
Style
Lens
Color
Legend
Legend
Orientation
ORIENTATION
3
1 CONTURA X, XI & XII LENS SEPARATELY
VVL
Contura X, XI & XII top piece of 2-piece lens separately:
2 LENS STYLE3
1 Bar lens
2 One Piece Square lens
3 Bottom of Two-Piece Square lens5
1 TOP OF LENS SEPARATELY
VVT
VVT 1
3 TRANSLUCENT LENS COLOR
1 Clear
2 White
3 Amber
4 Green4
5 Red
6 Blue4
1
2
2 COLOR
1 Clear 2 Smoke 3 White
Lens Separately
Color
4 LENS OR BODY LEGEND2
00 - No Legend
21
OFF
22
23
24
Contura X, XI & XII actuator lens assembly:
ON
O
I
25
O
F
26 O
27 O
28 I
N
top lens
actuator stem
F
two piece
lens assembly
For additional legend options & codes, visit us at www.carlingtech.com.
}
posts mount toward actuator stem
bottom lens
ORIENTATION OF
ACTUATOR/LENS IN PANEL
1 piece lens/bar lens are positioned the same as bottom lens for assembly,
minus the top lens. Lenses snap in from bottom.
3
5 LEGEND ORIENTATION
ORIENTATION
1
0
1
2
3
4
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
Notes:
1
If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2
must be chosen.
Center of actuator marking not available for Contura XII.
Legend is not available for bar style lens.
ORIENTATION
4
ORIENTATION
2
2
3
4
5
Not recommended with neon lamps.
ORIENTATION
3
Must also order top piece of 2 piece square lens separately.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
10
V-Series Contura Sealed Rocker Switch Accessories
Easily integrate Contura products into your system, with Contura Accessories
Contura Connectors
Q.C. SELECTION GUIDE
WIRE
PART NO
RANGE
COMPANY
SERIES
ORIEN-
TATION
TIN
PLATED
BRASS
2
PLAIN
BRASS
AWG
MM
(REF)
02965580
02965471
02965470
02965469
12
3.0
12010601
(2)16-14
16-14
20-18
(2)1.0-2.0
1.0-2.0
.5-.8
PACKARD
58 SERIES
B
TANG
06288318
12084590
12052224
10
12
5.0
3.0
12015870
12020035
12015869
12052222
16-14
(2)22-18
20-18
20-22
16-12
(2) 16
18-14
22-18
1.0-2.0
(2).5-.8
.5-.8
PACKARD
METRI-PACK
630 SERIES
TANG SYMBOL =
SHOWS ORIENTATION OF TANG IN SLOT
A
B
SYMBOL
12015832
60253-1
.35-.5
1.3-3
60253-2
AMP
(2) 1.3
.8-2
250 SERIES
FASTIN-FASTON
42100-1
60295-1
42100-2
60295-2
.3-.9
NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
.820[20.83]
.820[20.83]
.770[19.56]
.920[23.37]
.920[23.37]
1.170[29.72]
A
A
B
A
B
A
B
PACKARD 630
PACKARD 630
VC2
PACKARD 630
PACKARD 630
VC1
VC1
VC2
.950[24.13]
B
AMP,
58
AMP, PACKARD 58
AMP
AMP
10P3ACKARD
2
1
8
7 4
5
69
10 3
2
1
8
7
4
5
6 9
AMP, PACKARD 58
AMP, PACKARD 58
3
2
1
8
7
4
5
6
1.266[32.16]
1.466[37.24]
1.266[32.16]
1.466[37.24]
1.250[31.75]
MARKING DETAIL
FRONT VIEW
MARKING DETAIL
REAR VIEW
MARKING DETAIL
FRONT VIEW
MARKING DETAIL
REAR VIEW
MARKING DETAIL
FRONT VIEW
MARKING DETAIL
REAR VIEW
VC1
VC2
VCH
CONNECTOR HOUSING
(For AMP terminals only)
CONNECTOR HOUSING
CONNECTOR HOUSING
Contura X Boot (P/N VB1-01)
Additional V-Series Ratings
1
.4VA @ 28VDC Resistive
4
10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings
10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified
15A 125VAC 1/2 HP, 12(2)A 125 VAC μ T85
15A 125VAC 1/2 HP, 12(6)A 125 VAC T85
10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(2)A 250 VAC μ T85
10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(6)A 250 VAC T85
15A 24V
51
62
72
82
92
B
1.050[26.67]
2.000[50.80]
.757[19.23]
C
D
E
20A 18V
20A 12V
20A 14V, 10A 14VT (circuits 1, 4, A, & D only)
10A 14V, 6A, 14VT (circuit G only)
F
G
H
L
20A 6V
20A 3V
Contura II, III, IV & V Actuator Removal Tool
15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L
.4VA/20A 12V (combi-contact)
(combination gold/silver contacts for borderline dry circuit applications)
.4VA/15A 24V (combi-contact)
(P/N VRT)
M
3.99 [101.35]
O T P
N
INSERT POINTS UNDER
(combination gold/silver contacts for borderline dry circuit applications)
ACTUATOR
HOLD FLUSH ON BRACKET AND PUSH
IN
.900 [22.86]
TOP
NOTES
Consult factory to determine availability for individual circuits and their HP rating.
1.
2.
Not avaiable with Contura 7 or 14 rocker styles.
Ratings 6 - 9 are UL, CSA & VDE certified, require terminations A or B for double
pole circuits, & are not available with illumination circuits 4, 8, D, J, N, & T or with
wire lead or solder lug terminations.
Circuits 1, 4, A, D, H, M & E are not available with rating 6 & 8. Rating 7 & 9 only available
with circuits 1, 4, A & D. Circuits 2, 3, 5, 7, 8, K, L are 1/2 HP 250VAC only with rating 8.
Ratings 6 & 7 must specify lamp code 1 (125VAC neon). Ratings 8 & 9 must specify lamp
code 2 (250VAC neon). Rating L available with circuits 1, 4, A & D only.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
V-Series Contura Sealed Rocker Switch Accessories
11
Contura Mounting Panels
Dimensional Specifications: in. [mm]
Contura Hole Plug
Dimensional Specifications: in. [mm]
1.450 [36.83]
TEST CUT
HOLE IN
VHP
.830 [21.08]
ACTUAL
CONTURA II,III HOLE PLUG
MATERIAL
1.240 [31.50]
1.820 [46.23]
VHP
.430 [10.92]
CONTURA II,III HOLE PLUG
VH2
STANDARD HOLE PLUG
(With wing serrations)
VH1
STANDARD HOLE PLUG
(No wing serrations)
(With VC1 connector attached)
2.000 [50.80]
1.067 [27.10]
DETAIL VIEW
VH1,VH3 & VH5
HOLE PLUGS
(No wing serrations
for ease of removal)
VH3
VH4
CONTURA IV HOLE PLUG
(No wing serrations)
CONTURA IV HOLE PLUG
(With wing serrations)
1.928 [48.97]
1.020 [25.91]
DETAIL VIEW
VH2,VH4 & VH6
HOLE PLUGS
VH5
VH6
CONTURA V HOLE PLUG
(No wing serrations)
CONTURA V HOLE PLUG
(With wing serrations)
(With wing serrations)
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
12
Reps & Contact
Authorized North America Sales Representatives
Carling extensive sales representative network group is strategically located and ready to answer any
questions. Find your local representative by clicking on a group name on the map below or by visiting
www.carlingtech.com/findarep.
Matera
W. Canada
Matera
E. Canada
MIDWEST
DM
Michigan
TEMCO Northwest
ND
SD
WA
OR
NORTHERN
Hanna Lind Ltd.
MT
ME
VT
WI
MN
Melody
Sierra
NH
Emery
L D. Allen
MI
ID
Norris
MA
NY
WY
CT
«
IA
DM Assoc
IN
PA
RI
Bridge Marketing
NE
OH East
Pacent
TSI North
Omega Limited
CO
Dy-tronix Inc.
DM
NJ
NV
IL
DE
Assoc
WV
MD
TSI
KS
UT
KY
VA
CA
MO
TN
NC
SC
Luscombe
Engineering
Signal
OK
Enterprises
WEST
AR
Pinnacle Marketing
AZ
NM
Sunbelt Components
MS
AL
GA
TX
SOUTHEAST
LA
DM Mexico
El Paco, Mexico
ProRep
Solutions
Patricia Ortiz
Matrix
FL
Central America
South America
LATIN AMERICA
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
|
Notes
13
* Intentionally left blank
Email: sales@carlingtech.com • Application Support: team2@carlingtech.com
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
East Region Sales Office, CT • ersm@carlingtech.com
Midwest Region Sales Office, IL • mrsm@carlingtech.com
West Region Sales Office, CA • wrsm@carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 • Fax: Int + 852-2736-9332
Email: sales@carlingtech.com.hk
Shenzhen, China • shenzhen@carlingtech.com
Shanghai, China • shanghai@carlingtech.com
Pune, India • india@carlingtech.com
Kaohsiung, Taiwan • taiwan@carlingtech.com
Yokohama, Japan • japan@carlingtech.com
Europe/Middle East/Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Int + 44 1392-364422 • Fax: Int + 44 1392-364477
Email: ltd.sales@carlingtech.com
GmbH, Germany • gmbh@carlingtech.com
SAS, France • sas@carlingtech.com
REV_SW_V_07_2014
相关型号:
VKD1S00B-AZY00-000
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VKD1S00B-BZB00-000
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VKD1S00B-BZC00-000
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VKD1S00B-CZB00-000
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VKD1S00B-EZC00-000
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VKD1S00C-00000-000
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VKD1S00C-AZC00-000
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VKD1S00C-BZC00-000
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VKD1S00X-XZZ00-000-XTX1
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VKD2AH0C-A9CH5-100
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
VKD2U664-JLS00-000
Rocker Switch, DPDT, On-off-(on), Momentary, 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,
Carling Techn
©2020 ICPDF网 联系我们和版权申明